Test Code LAB40 Vancomycin Random

Test Performed By

Cayuga Medical Center, Main Laboratory

Container Name

SST

Day(s) and Time(s) Test Performed

Monday through Sunday; Continuously

List Price

$85.00

CPT Codes

80202

Temperature

Refrigerated

Clinical and Interpretive

Measurement of random vancomycin levels may be useful in monitoring adequacy of drug concentration during vancomycin therapy.

This unit code is used whenever a specimen is submitted or collected without collection timing information. Random levels may be ordered when attempting to determine when to dose vancomycin in patients with renal impairment or those undergoing dialysis.

Vancomycin is an antibiotic used to treat infections caused by gram-positive organisms that are resistant to beta-lactam antibiotics, such as methicillin-resistant staphylococci (MRSA), Staphylococcus viridans group, penicillin/cephalosporin-resistant Streptococcus pneumoniae, and penicillin/ampicillin-resistant Enterococcus species. The oral formulation, which is not absorbed, is used in the treatment of pseudomembranous colitis caused by Clostridium difficile. Vancomycin is also used when patients are intolerant or allergic to beta lactams.

Vancomycin has been associated with nephrotoxicity and ototoxicity, although it appears that many of these reports reflected impurities in early formulations. Monitoring of vancomycin-related nephrotoxicity is recommended only for patients with reduced renal function, those receiving aggressive or prolonged vancomycin regimens, or those at high risk including patients comedicated with other nephrotoxic agents.

Trough concentrations are recommended for therapeutic monitoring of vancomycin, preferably acquired at steady state (just before fourth dose). To avoid development of resistance, vancomycin trough levels should remain >10 mcg/mL. Complicated infections require higher target levels, typically 15 to 20 mcg/mL. Peak concentrations do not correlate well to efficacy or nephrotoxicity, but may be useful for pharmacokinetic studies or for select patients.

Trough levels correlate better with efficacy than peak levels, with target trough levels of 10 and 20 mcg/mL, depending on the type of infection.

Peak levels are not recommended for monitoring, except in select circumstances such as when performing pharmacokinetic analyses (eg, area under the curve [AUC] determinations). Typical peak levels are between 25 and 50 mcg/mL.

Specimen Type

Serum

Specimen Volume

6 mL

Minimum Specimen Volume

4 mL

Specimen Stability

Stability: 3 days